CONTROLS DISTRIBUTOR AND SOLUTION PROVIDER
Yorkland Controls + Environmental Solutions is a leading distributor of HVAC control systems. We believe in providing the right product for the right application - regardless of brand.
Home
About Us
Resources
Training
Programs
Products
Services
Tech Support
Contact Us

 

 
Energy Saving Calculator
   

Use this Energy Savings Calculator to discover the possible savings and environmental impact of switching to more efficient burners and boilers. Just enter your data in the boxes and your results will show up in the blue shaded areas.

HP= Output in BTUH/33472

Burner/Boiler operating Values - Present
Burner/Boiler Output Rating: HP
From Data Plate
Burner/Boiler Average Input: %
Average firing rate as determined by boiler operation/load
Burner/Boiler Average Output: HP
Burner/Boiler Average BTU Output: BTU/Hr
PresentBurner/Boiler Efficiency: %
As determined by combustion analyzer
Burner/Boiler Average BTU Input: BTU/Hr
Burner/Boiler Annual Run Hours: Hours
As determined by boiler on time/usage
Fuel Cost: $ per M3
As determined by supplier
Annual Fuel Cost: $
Estimated Burner/Boiler Efficiency Savings
Removal of Linkage Wear (0 to 1.0): %
Linkage systems have wear over time. Linkageless systems have no hysteresis across actuator stroke and typically operate with 0.1% accuracy.
Improved Combustion (0.5 to 3.0): %
Linkage systems cannot maintain consistent excess
air across the firing curve.
Linkage less systems can maintain consistent excess
air across the firing curve, reducing stack temperature
and emissions.
Increased Turndown (0.5 to 1.5): %
Linkage systems lite-off and minimum modulation
positions are typically the same.
Linkage less system lite-off and minimum modulation
positions are independent, increased turndown.
Total Efficiency Savings: %
Burner Boiler Operating Values – Projected
Burner/Boiler Output Rating: HP
Burner/Boiler Average Input: %
Burner/Boiler Average Output: HP
Burner/Boiler Average BTU Output: BTU/Hr
Present Burner/Boiler Efficiency: %
Efficiency cannot exceed 100%. If it does, adjust the input values you entered.
Burner/Boiler Average BTU Input: BTU/Hr
Burner/Boiler Annual Run Hours: Hours
Fuel Cost $ per M3
Annual Fuel Cost:
Financial Calculations and Environmental Impact
Projected Annual Fuel Savings: $ M3
Total Number of Boilers:
Total Fuel Savings:
Estimated Installation Costs:
Projected Return on Investment: Years
Total Carbon Emissions Prevented: lbs Metric Tonnes
Carbon emissions prevented based on 120 lbs CO2 released by 1,000,000 BTU
Equivalent number of Cars: Equivalent # of cars removed from road: Based on EPA estimate of 4.62 Metric Tonnes of CO per passenger car / year ( http://www.usctcgateway.net/tool/ )
NOTE: These are estimated savings. For dual fuel systems, calculate savings for each fuel for a total savings.
   © copyright 2003 | Yorkland Controls Inc.| all rights reserved| Powered by Interstrata Inc.